Back to Isotope Catalog
R-11005

DL-Epinephrine (d6)

Stable isotope standard for analytical research and method development.

Module Type
Stable Isotope Standards
Category
Hormones
CAS
1219803-77-6
Unlabeled CAS
329-65-7
PubChem CID
49849558
Molecular Formula
C9H7D6NO3
Molecular Weight
189.24
AI Isotope Property & Application AnalysisShow

Isotope Summary

Labels
D6
Labeled atoms
6
Isotope positions
Partially confirmed in structure
Calculation reliability
Medium, some information should be confirmed

Mass & MS Parameters

Unlabeled exact mass
183.089543 Da
Labeled exact mass
189.127204 Da
Exact mass shift
6.03766 Da
Nominal mass shift
6
Ionm/zStatus
[M+H]+190.13448Theoretical
[M+Na]+212.116422Theoretical
[M+NH4]+207.161027Theoretical
[M-H]-188.119927Theoretical

Label Stability

Overall
Moderate risk
Calculation reliability
Medium, some information should be confirmed
  • Carbon-bound deuterium is evaluated by local chemical environment; isotope effects should still be checked experimentally.

Internal Standard Suitability

Rating
Medium
Chromatographic similarity
Possible isotope effect
Natural isotope overlap
Low
  • Exact mass separation is 6.03766 Da; MS channel separation should be verified in the final method.
  • The unlabeled parent mass was derived from the isotope structure because a curated parent structure was not matched.
  • Overall suitability: Medium.

Recommended Applications

LC-MS/MS Quantitative Internal Standard
Recommended

LC-MS/MS Quantitative Internal Standard is classified as Recommended based on isotope mapping, mass separation, and label-stability rules.

Isotope Dilution Mass Spectrometry
Recommended

Isotope Dilution Mass Spectrometry is classified as Recommended based on isotope mapping, mass separation, and label-stability rules.

GC-MS Internal Standard
Possible

GC-MS Internal Standard is classified as Possible based on isotope mapping, mass separation, and label-stability rules.

Bioanalytical Method Development
Recommended

Bioanalytical Method Development is classified as Recommended based on isotope mapping, mass separation, and label-stability rules.

AI Interpretation

This analysis is based on isotope-aware structure data. The compound contains D6, with an exact mass shift of 6.03766 Da. Label stability is assessed as Moderate risk, and internal-standard suitability is Medium. These results support analytical method development and require experimental validation.

AI-assisted analytical guidance is intended for method-development support. Actual isotope stability, chromatographic behavior, fragmentation and MRM transitions should be experimentally validated.