Back to Isotope Catalog
R-10055

Vitamin B1 (13C3)

Stable isotope standard for analytical research and method development.

Module Type
Stable Isotope Standards
Category
Metabolites
CAS
1257525-77-1
Unlabeled CAS
1257525-77-1
PubChem CID
71310993
Molecular Formula
C9[13C]3H18Cl2N4OS
Molecular Weight
341.24
AI Isotope Property & Application AnalysisShow

Isotope Summary

Labels
13C4
Labeled atoms
4
Isotope positions
Partially confirmed in structure
Calculation reliability
Medium, some information should be confirmed

Mass & MS Parameters

Unlabeled exact mass
336.057838 Da
Labeled exact mass
340.071257 Da
Exact mass shift
4.013419 Da
Nominal mass shift
4
Ionm/zStatus
[M+H]+341.078533Theoretical
[M+Na]+363.060475Theoretical
[M+NH4]+358.10508Theoretical
[M-H]-339.06398Theoretical

Label Stability

Overall
Low risk
Calculation reliability
Medium, some information should be confirmed
  • Skeleton-bound 13C/15N labels are generally non-exchangeable under normal analytical handling.

Internal Standard Suitability

Rating
High
Chromatographic similarity
Expected high similarity
Natural isotope overlap
Low
  • Exact mass separation is 4.013419 Da; MS channel separation should be verified in the final method.
  • The unlabeled parent mass was derived from the isotope structure because a curated parent structure was not matched.
  • Overall suitability: High.

Recommended Applications

LC-MS/MS Quantitative Internal Standard
Recommended

LC-MS/MS Quantitative Internal Standard is classified as Recommended based on isotope mapping, mass separation, and label-stability rules.

Isotope Dilution Mass Spectrometry
Recommended

Isotope Dilution Mass Spectrometry is classified as Recommended based on isotope mapping, mass separation, and label-stability rules.

Metabolic Tracing
Possible

Metabolic Tracing is classified as Possible based on isotope mapping, mass separation, and label-stability rules.

Bioanalytical Method Development
Recommended

Bioanalytical Method Development is classified as Recommended based on isotope mapping, mass separation, and label-stability rules.

AI Interpretation

This analysis is based on isotope-aware structure data. The compound contains 13C4, with an exact mass shift of 4.013419 Da. Label stability is assessed as Low risk, and internal-standard suitability is High. These results support analytical method development and require experimental validation.

AI-assisted analytical guidance is intended for method-development support. Actual isotope stability, chromatographic behavior, fragmentation and MRM transitions should be experimentally validated.